Permit Details

Permit Search

Permit

New Residential Construction

3511 SW PINEMOUNT RD
LAKE CITY, FL 32024

Permit #
000045118
Application #
55657
Status Completed
  1. Submitted Jul 12, 2022
  2. Issued Aug 8, 2022
  3. Expires Nov 15, 2023
  4. Completed May 19, 2023

Property

Parcel #
02806-010
Owner
Ward Jessica N, Ward Christopher G
Acres
5.19
Subdivision
—
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
12" ABOVE THE HIGHEST ADJACENT GRADE
Fema map number
12023C0270C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30
Setback Side 1
25
Setback Side 2
25
Setbacks Rear
25
Stories
1
Heated Area (Sqft)
2068
Total Area (Sqft)
3246
Building Height
20
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0535
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Plan Review - Building Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Plumbing Approved
  8. Plan Review - Fuel/Gas Approved
  9. Plan Review - Reviewed
  10. Zoning Review - Reviewed
  11. Final Review - Documents Required
  12. Final Review - Documents Required
  13. Final Review - Documents Required
  14. Final Review - Documents Required
  15. Final Review - Reviewed
  16. Final Review - Reviewed
  17. Final Review - Reviewed
  18. Final Review - Payment Needed
  19. Permit Issued
  20. Final Review - Payment Needed

Contractors

  • Matthew Hentzelman

    Trademark Construction Group Inc.

    License
    CGC1514780
    Title
    General Contractor
    Role
    Contractor

    County License & State License Expired.

  • Roger Whiddon

    Lake City Plumbing Inc

    License
    CFC1428686
    Title
    Cert Plumbing
    Role
    Subcontractor
  • Michael Towne

    Towne Construction Group

    License
    CCC1330125
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • David P Wood

    Wood's Electrical Services Inc

    License
    EC13002213
    Title
    Electrical Contractor
    Role
    Subcontractor
  • David E Hall

    David Hall's Air Cond & Heating Svc,inc.

    License
    CAC057424
    Title
    Class B A/c Contractor
    Role
    Subcontractor

    Workers Comp Expired.

Inspections

  1. Sep 22, 2022

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. Sep 22, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Sep 22, 2022

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  4. Sep 22, 2022

    Release to power company

    Inspected by Matt Forsyth

  5. Oct 28, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  6. Nov 16, 2022

    Passed: Building - Slab

    Inspected by Matt Forsyth

  7. Dec 28, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  8. Dec 28, 2022

    Failed: Building - Ext Strapping/Wall Sheathing

    Need Straps On End Wall Bracing Also Strapping On Porch Column

    Inspected by Matt Forsyth

  9. Feb 6, 2023

    Passed: Building - Framing

    Endwall Strapping Confirmed

    Inspected by Matt Forsyth

  10. Feb 6, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  11. Feb 6, 2023

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  12. Feb 6, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  13. Feb 17, 2023

    Failed: Building - Insulation

    Insulation Installation Needs Improvement, Lots Of Areas In Building That Have Insulation Mashed Around Bolts With No Insulation Behind Bolts, Several Places Though-out House Insulation Is Short Of Fitting The Hole It Is Intended To Insulalate

    Inspected by Gary Pitzer

  14. Feb 20, 2023

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  15. Feb 28, 2023

    Septic Release Inspection

    Inspected by Health Dept

  16. Apr 12, 2023

    Passed: Electrical - Permanent Power

    Inspected by Matt Forsyth

  17. Apr 12, 2023

    Release to power company

    Inspected by Matt Forsyth

  18. May 19, 2023

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents