Permit Details

Permit Search

Permit

Mobile Home

1296 SW BARON GLN
FORT WHITE, FL 32038

Permit #
000045027
Application #
55539
Status Completed
  1. Submitted Jul 5, 2022
  2. Issued Jul 22, 2022
  3. Expires Oct 2, 2023
  4. Completed May 2, 2023

Property

Parcel #
03752-421
Owner
Walstrom Kevin J, Walstrom Melanie E
Acres
4.72
Subdivision
Southern Meadows Phase 3
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
85.5'
Requirement needed
By Final Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0390C
In floodway
N
Mobile Home is a:
Double Wide
Year Built
2022
Width (Ft.In)
32
Length (Ft.In)
64
Driveway access to home:
Existing Drive
Installation Decal #
90747
Septic #
22-0575
Setbacks Front
30'
Setback Side 1
25'
Setbacks Rear
25'
Dev Permit #
F023-
Setback Side 2
25'
Are you applying for a 5 year temporary permit?
No
Serial #
DVAL12310636AB
Wind Zone?
2
Residential or Commercial Use?
Residential
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Zoning Review - Reviewed
  5. Final Review - Documents Required
  6. Plan Review - Reviewed
  7. Final Review - Corrections Needed
  8. Final Review - Reviewed
  9. Final Review - Payment Needed
  10. Permit Issued

Contractors

  • Ernest S Johnson

    Dependable Mobile Home Service

    License
    IH1025249
    Title
    Mh Installer (ih)
    Role
    Contractor

    County License & State License Expired.

  • James D Williams

    Affordable Electrical Services Inc

    License
    EC13007092
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License Expired.

  • Timothy D Shatto

    Shatto Heating & Air, Inc.

    License
    CAC057875
    Title
    A/c Class B
    Role
    Subcontractor

Inspections

  1. Apr 3, 2023

    Septic Release Inspection

    Inspected by Health Dept

  2. Apr 4, 2023

    Cancelled: Mobile Home - Mobile Home Set-Up Final

    Inspected by Emaleigh Williams

  3. Apr 4, 2023

    Cancelled: Engineering - Setbacks

    Inspected by Emaleigh Williams

  4. Apr 5, 2023

    Failed: Engineering - Setbacks

    Need Engineer Letter On Elevation

    Inspected by Gary Pitzer

  5. Apr 5, 2023

    Passed: Mobile Home - Mobile Home Set-Up Final

    Pass Electric Service And Safety Portions Of Permit,but We Need Elevation Letter From Engineer

    Inspected by Gary Pitzer

  6. Apr 5, 2023

    Release to power company

    Inspected by Gary Pitzer

  7. May 2, 2023

    Certificate-Release Certificate

    Inspected by Gary Pitzer