Permit Details

Permit Search

Permit

New Residential Construction

265 SW FIELDSTONE CT
LAKE CITY, FL 32024

Permit #
000044661
Application #
54869
Status Completed
  1. Submitted May 17, 2022
  2. Issued Jun 10, 2022
  3. Expires Jul 22, 2023
  4. Completed Jan 26, 2023

Property

Parcel #
02438-150
Owner
Weatherly Glen Van, Weatherly Tavia
Acres
0.51
Subdivision
Emerald Cove Phase 2
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
137'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0290D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2105
Total Area (Sqft)
2807
Building Height
18
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0426
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. City of Lake City Notified of Application within Utility Service Areas LC_GAS,.
  2. City of Lake City
  3. Point Review - Received-Hard Copy Application
  4. Point Review - Reviewed
  5. Plan Review - Building Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Mechanical Approved
  8. Plan Review - Plumbing Approved
  9. Plan Review - Fuel/Gas Approved
  10. Zoning Review - Reviewed
  11. Final Review - Reviewed
  12. Final Review - Payment Needed
  13. Final Review - Payment Needed
  14. Permit Issued
  15. Point Review - Reviewed
  16. Point Review - Reviewed
  17. Final Review - Payment Needed
  18. Final Review - Payment Needed

Contractors

  • Mark Bauer

    Gibraltar Contracting Llc

    License
    CBC1259633
    Title
    Cert Building
    Role
    Contractor

    County License & State License Expired.

  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor
  • James Butler Jr

    Butler Plumbing Of Gainesville Inc

    License
    CFC057960
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Lewis G Walker

    Lewis Walker Roofing Inc

    License
    CCC1333551
    Title
    Cert. Roofing
    Role
    Subcontractor

Inspections

  1. Jun 22, 2022

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. Jun 22, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Jul 13, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  4. Jul 19, 2022

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Jul 21, 2022

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  6. Jul 21, 2022

    Release to power company

    Inspected by Troy Crews

  7. Aug 15, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  8. Aug 15, 2022

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  9. Sep 1, 2022

    Passed: Building - Framing

    Inspected by Troy Crews

  10. Sep 1, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  11. Sep 1, 2022

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  12. Sep 1, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  13. Sep 7, 2022

    Passed: Building - Insulation

    Walls And Some Ceiling

    Inspected by Matt Forsyth

  14. Nov 18, 2022

    Failed: Electrical - Permanent Power

    Undersized Bear Copper Ground Wire Septic And Drive Releases

    Inspected by Matt Forsyth

  15. Nov 22, 2022

    Passed: Electrical - Permanent Power

    Need Drive Release-- Do Not Issue Co Until Confirmation Rec'd From Sallie At Eh Even Though Septic Rec'd-- Mg

    Inspected by Troy Crews

  16. Nov 22, 2022

    Septic Release Inspection

    Do Not Issue Co Until Confirmation Rec'd From Sallie At Eh Even Though Septic Rec'd-- Mg

    Inspected by Health Dept

  17. Nov 28, 2022

    Release to power company

    Do Not Issue Co Until Confirmation Rec'd From Sallie At Eh Even Though Septic Rec'd-- Mg

    Inspected by Melissa Garber

  18. Jan 23, 2023

    Passed: Building - Final

    Waiting For Environmental Health--- Confirmation Rec'd 1/26/2023

    Inspected by Matt Forsyth

  19. Jan 26, 2023

    Release to power company

    Inspected by Melissa Garber

  20. Jan 26, 2023

    Certificate-Release Certificate

    Inspected by Matt Forsyth

Documents