Permit Details

Permit Search

Permit

New Residential Construction

1542 SW LITTLE RD
LAKE CITY, FL 32024

Permit #
000044659
Application #
54486
Status Completed
  1. Submitted Apr 26, 2022
  2. Issued Jun 10, 2022
  3. Expires Dec 19, 2023
  4. Completed Jun 22, 2023

Property

Parcel #
03390-005
Owner
Martinez Logan, Martinez Irving
Acres
0.98
Subdivision
—
Zoning
A-3
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0383D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2710
Total Area (Sqft)
4251
Building Height
18
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0429
If Other, explain the use of the structure.
Slab and some walls will be left from original residence
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Plan Review - Documents Required
  5. Plan Review - Documents Required
  6. Plan Review - Documents Required
  7. Plan Review - Documents Required
  8. Plan Review - Documents Required
  9. Plan Review - Documents Required
  10. Zoning Review - Reviewed
  11. Plan Review - Plumbing Approved
  12. Plan Review - Mechanical Approved
  13. Plan Review - Electrical Approved
  14. Plan Review - Building Approved
  15. Plan Review - Reviewed
  16. Final Review - Documents Required
  17. Final Review - Reviewed
  18. Final Review - Payment Needed
  19. Permit Issued
  20. Final Review - Payment Needed

Contractors

  • Donald E Little Jr

    Don Little Construction & Roofing Inc

    License
    CBC1260286
    Title
    Cert. Building
    Role
    Contractor

    County License & State License Expired.

  • Daniel Mossburg

    Live Oak Plumbing, Inc.

    License
    CFC1427438
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Donald Little, Jr.

    Don Little Construction & Roofing Inc

    License
    CCC1330420
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License Expired.

  • Thomas Bucchi

    Ace Heat & Air Inc

    License
    CAC058170
    Title
    Class B A/c Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance Expired.

  • Ryan Felknor

    Felknor Electric, Inc.

    License
    EC13003153
    Title
    Electrical Contractor
    Role
    Subcontractor

Inspections

  1. Jun 24, 2022

    Passed: Building - Footer

    Stemwall Footing

    Inspected by Matt Forsyth

  2. Jun 24, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Jul 13, 2022

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Matt Forsyth

  4. Jul 13, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  5. Jul 18, 2022

    Passed: Building - Footer

    Inspected by Troy Crews

  6. Jul 18, 2022

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  7. Jul 18, 2022

    Passed: Building - Monolithic Slab

    North End

    Inspected by Troy Crews

  8. Jul 25, 2022

    Passed: Building - Footer

    Complets Footer's

    Inspected by Matt Forsyth

  9. Jul 25, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  10. Jul 25, 2022

    Passed: Building - Monolithic Slab

    Complets

    Inspected by Matt Forsyth

  11. Aug 17, 2022

    Passed: Building - Lintel/Tie Beam

    Inspected by Matt Forsyth

  12. Aug 17, 2022

    Passed: Building - Masonry Wall Reinforcing

    Inspected by Matt Forsyth

  13. Aug 17, 2022

    Passed: Building - Vertical Cells/Columns

    Inspected by Matt Forsyth

  14. Oct 19, 2022

    Rescheduled 10/20/2022:Building - Roof Decking

    Inspected by Matt Forsyth

  15. Oct 20, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  16. Dec 8, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  17. Dec 8, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  18. Dec 8, 2022

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  19. Dec 8, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  20. Feb 1, 2023

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  21. Apr 24, 2023

    Septic Release Inspection

    Inspected by Health Dept

  22. Apr 28, 2023

    Passed: Electrical - Permanent Power

    Inspected by Matt Forsyth

  23. Apr 28, 2023

    Release to power company

    Inspected by Matt Forsyth

  24. Jun 22, 2023

    Passed: Building - Final

    Inspected by Gary Pitzer

Documents