Permit Details

Permit Search

Permit

New Residential Construction

10640 SW COUNTY ROAD 240
LAKE CITY, FL 32024

Permit #
000044386
Application #
54574
Status Completed
  1. Submitted Apr 28, 2022
  2. Issued May 10, 2022
  3. Expires Apr 8, 2023
  4. Completed Nov 23, 2022

Property

Parcel #
00455-004
Owner
Sauls Perry R, Sauls Betty T
Acres
5.00
Subdivision
—
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0370C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1944
Total Area (Sqft)
3384
Building Height
20
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0355
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Plan Review - Documents Required
  4. Plan Review - Building Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Plumbing Approved
  8. Plan Review - Reviewed
  9. Zoning Review - Reviewed
  10. Final Review - Documents Required
  11. Final Review - Documents Required
  12. Final Review - Reviewed
  13. Final Review - Payment Needed
  14. Permit Issued
  15. Final Review - Payment Needed

Contractors

  • Brian T Giebeig

    Trent Giebeig Construction,inc.

    License
    CRC1330693
    Title
    Residential Contractor
    Role
    Contractor
  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Derrick L Williams

    Dl Williams Heating & Cooling Llc

    License
    CAC1816913
    Title
    Class "b" A/c Contractor
    Role
    Subcontractor
  • Kenneth R Roche

    Ken Roche Plumbing Inc Dba Plumbing Now

    License
    CFC1426527
    Title
    Plumbing Contractor
    Role
    Subcontractor

Inspections

  1. May 11, 2022

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. May 11, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. May 25, 2022

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  4. May 25, 2022

    Release to power company

    Inspected by Matt Forsyth

  5. May 27, 2022

    Passed: Building - Slab

    Inspected by Matt Forsyth

  6. Jul 12, 2022

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  7. Jul 12, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  8. Jul 12, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  9. Jul 12, 2022

    Passed: Building - Strapping

    Inspected by Matt Forsyth

  10. Jul 12, 2022

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  11. Aug 5, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  12. Aug 5, 2022

    Passed: Mechanical - Rough In

    Nice Job

    Inspected by Matt Forsyth

  13. Aug 5, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  14. Aug 18, 2022

    Passed: Building - Insulation

    Walls Only

    Inspected by Matt Forsyth

  15. Oct 10, 2022

    Passed: Electrical - Permanent Power

    Need Septic Released

    Inspected by Matt Forsyth

  16. Oct 13, 2022

    Release to power company

    Inspected by Melissa Garber

  17. Oct 13, 2022

    Septic Release Inspection

    Inspected by Health Dept

  18. Oct 13, 2022

    Cancelled: Electrical - Permanent Power

    Inspected by Matt Forsyth

  19. Nov 18, 2022

    Failed: Building - Final

    Hot Water Heater Piped To Outside Blower Door And Final Termite Needed For Final

    Inspected by Matt Forsyth

  20. Nov 23, 2022

    Certificate-Release Certificate

    Blower Door , Termite, And Drain Line Completed

    Inspected by Troy Crews

  21. Requested

    Plumbing/Gas - 1st Underground Rough–In

    Awaiting inspection

Documents