Permit Details

Permit Search

Permit

New Residential Construction

762 NW INDIAN SPRINGS DR
LAKE CITY, FL 32055

Permit #
000044258
Application #
54040
Status Completed
  1. Submitted Mar 24, 2022
  2. Issued Apr 25, 2022
  3. Expires Jun 5, 2023
  4. Completed Dec 7, 2022

Property

Parcel #
00167-015
Owner
Chad Vercher
Acres
4.91
Subdivision
Oakhaven
Zoning
A-3
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0260C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2236
Total Area (Sqft)
3566
Building Height
18
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0236
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - On Hold-Incomplete
  3. Point Review - Printed-Online Application
  4. Plan Review - Corrections Needed
  5. Plan Review - Building Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Mechanical Approved
  8. Plan Review - Plumbing Approved
  9. Plan Review - Fuel/Gas Approved
  10. Plan Review - Reviewed
  11. Zoning Review - Reviewed
  12. Zoning Review - Reviewed
  13. Final Review - Reviewed
  14. Final Review - Reviewed
  15. Final Review - Payment Needed
  16. Permit Issued
  17. Final Review - Payment Needed

Contractors

  • Jason Huddleston

    Red Door Homes Of North Central Florida Llc

    License
    CBC1262184
    Title
    Cert. Building
    Role
    Contractor

    County License Expired.

  • Ronald C Fletcher

    Fletcher Plumbing Inc

    License
    CFC057986
    Title
    Cert. Plumbing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Barry D Joye

    Energy Roofing Tech Se Llc (dba) Energy Roofing Companies

    License
    CCC1329523
    Title
    Roofing Contractor
    Role
    Subcontractor

    County License & State License & Workers Comp Expired.

  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Erik W Worthmann

    Comfort Temp Company Dba Ct Mechanical

    License
    CMC1249305
    Title
    Cert. Mechanical
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. May 24, 2022

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Anthony Aslan

  2. May 24, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  3. Jun 7, 2022

    Failed: Building - Footer

    All Water Supply Piping And Waste Pipe Need To Be Moved Touching Form Boards

    Inspected by Matt Forsyth

  4. Jun 7, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  5. Jun 8, 2022

    Passed: Building - Monolithic Slab

    Inspected by Matt Forsyth

  6. Jun 8, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  7. Jun 27, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  8. Jun 27, 2022

    Passed: Building - Wall Sheathing

    Check One Sheet Back Wall Need Nails

    Inspected by Matt Forsyth

  9. Jul 20, 2022

    Passed: Building - Framing

    Inspected by Anthony Aslan

  10. Jul 20, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  11. Jul 20, 2022

    Failed: Mechanical - Rough In

    Gaskets On All Boots

    Inspected by Anthony Aslan

  12. Jul 20, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  13. Jul 20, 2022

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Anthony Aslan

  14. Aug 24, 2022

    Rescheduled 8/25/2022:Building - Insulation

    Inspected by Matt Forsyth

  15. Aug 25, 2022

    Passed: Building - Insulation

    Walls Only

    Inspected by Matt Forsyth

  16. Sep 6, 2022

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  17. Sep 6, 2022

    Release to power company

    Inspected by Matt Forsyth

  18. Oct 4, 2022

    Cancelled: Electrical - 1st Underground Rough–In

    Inspected by Matt Forsyth

  19. Oct 4, 2022

    Cancelled: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  20. Oct 4, 2022

    Cancelled: Electrical - Temporary Service

    Inspected by Matt Forsyth

  21. Oct 4, 2022

    Passed: Electrical - Permanent Power

    Need Septic Released

    Inspected by Matt Forsyth

  22. Oct 13, 2022

    Release to power company

    Inspected by Melissa Garber

  23. Oct 13, 2022

    Septic Release Inspection

    Inspected by Health Dept

  24. Nov 9, 2022

    Cancelled: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  25. Dec 5, 2022

    Failed: Building - Final

    No Access To Building

    Inspected by Matt Forsyth

  26. Dec 5, 2022

    Cancelled: Building - Final

    Inspected by Matt Forsyth

  27. Dec 7, 2022

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents