Permit Details

Permit Search

Permit

New Residential Construction

649 SW LONCALA LOOP
FORT WHITE, FL 32038

Permit #
000043906
Application #
53513
Status Completed
  1. Submitted Feb 14, 2022
  2. Issued Mar 11, 2022
  3. Expires Feb 28, 2023
  4. Completed Sep 1, 2022

Property

Parcel #
00502-228
Owner
Welsh Joseph L Ii,
Acres
5.01
Subdivision
Ichetucknee Forest Phase 2
Zoning
ESA-2
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0460C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1377
Total Area (Sqft)
1558
Building Height
19
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0132
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Plan Review - Building Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Plumbing Approved
  8. Plan Review - Reviewed
  9. Zoning Review - Reviewed
  10. Final Review - Reviewed
  11. Final Review - Documents Required
  12. Final Review - Documents Required
  13. Final Review - Payment Needed
  14. Permit Issued
  15. Final Review - Payment Needed

Contractors

  • Stuart L Amira

    Amira Builders, Inc.

    License
    CRC1327171
    Title
    Cert. Residential
    Role
    Contractor

    County License & State License Expired.

  • James Butler Jr

    Butler Plumbing Of Gainesville Inc

    License
    CFC057960
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • David J Pabst

    Whittle Roofing Company, Inc.

    License
    CCC1326372
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License Expired.

  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Robert M Bounds

    Bounds Heating & Air Inc

    License
    CAC057642
    Title
    Class A A/c
    Role
    Subcontractor

Inspections

  1. Mar 29, 2022

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  2. Mar 29, 2022

    Release to power company

    Inspected by Matt Forsyth

  3. Apr 7, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  4. Apr 14, 2022

    Passed: Building - Monolithic Slab

    Inspected by Matt Forsyth

  5. Apr 14, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  6. Apr 14, 2022

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Matt Forsyth

  7. May 16, 2022

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  8. May 16, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  9. May 26, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  10. May 26, 2022

    Failed: Electrical - 2nd Rough-In

    Missing Smoke Detector In Hall

    Inspected by Matt Forsyth

  11. May 26, 2022

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  12. May 26, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  13. May 31, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  14. Jun 1, 2022

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  15. Jun 24, 2022

    Failed: Electrical - Permanent Power

    Conduit Needs To Be Run From Metercan To Power Pole. To Be Able To Release Power Need Septic Released

    Inspected by Matt Forsyth

  16. Jun 27, 2022

    Septic Release Inspection

    Inspected by Health Dept

  17. Jun 30, 2022

    Cancelled: Electrical - Permanent Power

    Inspected by Emaleigh Williams

  18. Jul 1, 2022

    Passed: Electrical - Permanent Power

    Inspected by Matt Forsyth

  19. Jul 1, 2022

    Release to power company

    Inspected by Matt Forsyth

  20. Aug 31, 2022

    Failed: Building - Final

    Outdoor Receptacles Have No Ground Fault Protection Need To Be Properly Labeled Impanel

    Inspected by Matt Forsyth

  21. Sep 1, 2022

    Passed: Building - Final

    Items Were Addressed

    Inspected by Matt Forsyth

Documents