Permit Details

Permit Search

Permit

New Residential Construction

174 SW CABOOSE DR
FORT WHITE, FL 32038

Permit #
000043749
Application #
49426
Status Completed
  1. Submitted Feb 9, 2022
  2. Issued Feb 22, 2022
  3. Expires Feb 19, 2023
  4. Completed Aug 29, 2022

Property

Parcel #
04059-120
Owner
Terry Craig A & Lisa G
Acres
0.64
Subdivision
Fort White Station
Zoning
—
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0490C
This is the construction of a
Single Family Dwelling
Setbacks Front
10'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
10'
Stories
1
Heated Area (Sqft)
1843
Total Area (Sqft)
2710
Building Height
18
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0473
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Plan Review - Reviewed
  4. Final Review - Documents Required
  5. Final Review - Documents Required
  6. Final Review - Documents Required
  7. Final Review - Documents Required
  8. Final Review - Documents Required
  9. Final Review - Documents Required
  10. Final Review - Documents Required
  11. Final Review - Documents Required
  12. Permit Issued
  13. Final Review - Payment Needed

Contractors

  • Jeffrey P Bokor

    Dwc Contracting, Inc.

    License
    CGC1517145
    Title
    General Contractor
    Role
    Contractor

    Liability Insurance Expired.

  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Samuel L Roberts

    Air Ducks Inc

    License
    CAC1817288
    Title
    Class "b" A/c
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • James Butler Jr

    Butler Plumbing Of Gainesville Inc

    License
    CFC057960
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Jeffrey Bokor

    Dwc Contracting Llc

    License
    CCC1329756
    Title
    Roofing Contractor
    Role
    Subcontractor

    Liability Insurance Expired.

Inspections

  1. Feb 25, 2022

    Release to power company

    Inspected by Anthony Aslan

  2. Feb 25, 2022

    Passed: Electrical - Temporary Service

    Inspected by Anthony Aslan

  3. Feb 25, 2022

    Release to power company

    Inspected by Anthony Aslan

  4. Mar 30, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  5. Apr 8, 2022

    Rescheduled 4/11/2022:Building - Monolithic Slab

    Inspected by Anthony Aslan

  6. Apr 8, 2022

    Cancelled: Engineering - Setbacks

    Inspected by Anthony Aslan

  7. Apr 11, 2022

    Cancelled: Building - Monolithic Slab

    Inspected by Melissa Garber

  8. Apr 11, 2022

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  9. Apr 11, 2022

    Passed: Building - Monolithic Slab

    Inspected by Anthony Aslan

  10. Apr 26, 2022

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  11. Apr 26, 2022

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  12. Apr 27, 2022

    Passed: Building - Strapping

    Inspected by Anthony Aslan

  13. Apr 27, 2022

    Passed: Building - Framing

    Inspected by Anthony Aslan

  14. May 13, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  15. May 13, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  16. May 16, 2022

    Failed: Mechanical - Rough In

    No Gasket On Supply And Return Boots, No Hanging Strap On Exhaust Fan Venting

    Inspected by Anthony Aslan

  17. May 17, 2022

    Rescheduled 5/18/2022:Mechanical - Rough In

    Inspected by Anthony Aslan

  18. May 18, 2022

    Passed: Mechanical - Rough In

    Gaskets Installed

    Inspected by Anthony Aslan

  19. May 20, 2022

    Passed: Building - Insulation

    Walls Only

    Inspected by Anthony Aslan

  20. May 26, 2022

    Septic Release Inspection

    Inspected by Health Dept

  21. Jun 23, 2022

    Passed: Electrical - Permanent Power

    Need Garage Door Or Lock On Panel

    Inspected by Anthony Aslan

  22. Jul 12, 2022

    Release to power company

    Garage Door Installed

    Inspected by Anthony Aslan

  23. Aug 23, 2022

    Passed: Building - Final

    Gfci In Hall Bath Open Ground/open Neutral.

    Inspected by Anthony Aslan

  24. Aug 29, 2022

    Certificate-Release Certificate

    Corrected

    Inspected by Anthony Aslan

Documents