Permit Information

New Residential Construction Permit

Address 394 SW TIMBERLAND CT
LAKE CITY, FL 32024
Parcel #: 02438-184
Acres:0.51
Owner:Cornerstone Developers Ii Llc
Subdivision:Emerald Cove Phase 2
Zoning:RSF-2
Flood Zone:X
District:3
Application #:52016
Permit #: 000043633
Related Permit:
Submitted:Tuesday, October 26, 2021
Issued:Wednesday, February 2, 2022
Expires:Thursday, June 30, 2022
Completed:Thursday, June 30, 2022
Status: Completed
Septic Release? Yes

Notes

ELEVATION CONFIRMATION REC'D @ 109.39'

Job Details

Elevation regulation Subdivision Plat
Finished floor requirement 107'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0290D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 1653
Total Area (Sqft) 2148
Building Height 17
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 21-1045
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Review Notes

10/8/2021 Point Review - Received-Hard Copy Application
10/8/2021 Point Review - Reviewed
10/12/2021 Plan Review - Building Approved
10/12/2021 Plan Review - Electrical Approved
10/12/2021 Plan Review - Mechanical Approved
10/12/2021 Plan Review - Plumbing Approved
10/12/2021 Plan Review - Reviewed
10/26/2021 Zoning Review - Reviewed
11/1/2021 Zoning Review - Reviewed
11/1/2021 Final Review - Documents Required
11/10/2021 Final Review - Documents Required
11/18/2021 Final Review - Documents Required
12/22/2021 Final Review - Documents Required
1/31/2022 Final Review - Payment Needed
2/2/2022 Permit Issued
5/23/2022 Final Review - Payment Needed
6/9/2022 Final Review - Payment Needed
6/10/2022 Final Review - Payment Needed

Contractors

Name / Business License Title Role
Jerry Castagna
Castagna Construction Inc
County License & State License & Liability Insurance & Workers Comp Expired.
CBC047842 Building Contractor Contractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Derrick L Williams
Dl Williams Heating & Cooling Llc
CAC1816913 Class "b" A/c Contractor Subcontractor
Frank Soucinek
Dependable Plumbing
County License & State License & Workers Comp & Employees Workers Comp Expired.
CFC057747 Plumbing Contractor Subcontractor
Darin L Summerlin
Summerlin Roofing Inc
CCC1326192 Roofing Contractor Subcontractor

Inspections

Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 2/18/2022
Passed: Building - Monolithic Slab Matt Forsyth 3/4/2022
Passed: Engineering - Setbacks Matt Forsyth 3/4/2022
Septic Release Inspection Health Dept 3/29/2022
Passed: Building - Roof Decking Matt Forsyth 4/13/2022
Passed: Building - Wall Sheathing Matt Forsyth 4/13/2022
Passed: Building - Framing Matt Forsyth 4/27/2022
Passed: Building - Strapping Matt Forsyth 4/27/2022
Passed: Mechanical - Rough In Matt Forsyth 4/27/2022
Failed: Plumbing/Gas - 2nd Rough-In Need Nail Plate Master Bath Water To Vainty Matt Forsyth 4/27/2022
Failed: Electrical - 2nd Rough-In Need Nail Plate Electric Panel Top Of Wall Matt Forsyth 4/27/2022
Cancelled: Building - Insulation Matt Forsyth 4/28/2022
Passed: Electrical - 2nd Rough-In Matt Forsyth 4/29/2022
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 4/29/2022
Passed: Building - Insulation Walls Only Matt Forsyth 4/29/2022
Failed: Electrical - Permanent Power Need Front Door Installed And Door Locks Troy Crews 5/25/2022
Passed: Electrical - Permanent Power Need Driveway Release Matt Forsyth 6/1/2022
Release to power company Melissa Garber 6/10/2022
Passed: Building - Final Matt Forsyth 6/30/2022

Documents

File Name Date File Size

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.