Permit Details

Permit Search

Permit

New Residential Construction

247 SW JEWEL LAKE DR
LAKE CITY, FL 32024

Permit #
000043292
Application #
52603
Status Completed
  1. Submitted Nov 18, 2021
  2. Issued Dec 3, 2021
  3. Expires Nov 28, 2022
  4. Completed Jun 1, 2022

Property

Parcel #
02439-244
Owner
Gsms Developers Inc
Acres
0.29
Subdivision
Reserve At Jewel Lake Phase 2
Zoning
PRD
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
125.10'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0290D
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
This is the construction of a
Single Family Dwelling
Heated Area (Sqft)
1636
Total Area (Sqft)
2316
Stories
1
Building Height
20
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Septic# (00-0000) or (X00-000)
x-CITY
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code

Status & Review History

  1. Application pending.
  2. Application Converted
  3. Point Review - On Hold-Incomplete
  4. Point Review - Printed-Online Application
  5. Final Review - Documents Required
  6. Plan Review - Building Approved
  7. Plan Review - Electrical Approved
  8. Plan Review - Mechanical Approved
  9. Plan Review - Plumbing Approved
  10. Plan Review - Reviewed
  11. Zoning Review - Reviewed
  12. Final Review - Email Sent
  13. Final Review - Documents Required
  14. Final Review - Complete
  15. Permit Issued
  16. Final Review - Payment Needed

Contractors

  • Gerald M Smith Sr

    S&s Construction Llc

    License
    CBC1254161
    Title
    Building Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Daniel Mossburg

    Live Oak Plumbing, Inc.

    License
    CFC1427438
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  • Lyndon J Rainbolt

    Rainbolt Tech Services,air Stream

    License
    EC13001835
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Workers Comp Expired.

  • Arthur (paul) P King Jr

    Pauls Heating & Air Inc

    License
    CAC1813957
    Title
    Cert Class B A/c
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. Jan 4, 2022

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Jan 4, 2022

    Passed: Engineering - Setbacks

    10 Ft 2 Inches West Side Per Contractor.

    Inspected by Troy Crews

  3. Jan 28, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  4. Feb 3, 2022

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Mar 15, 2022

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  6. Mar 15, 2022

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  7. Mar 17, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  8. Mar 18, 2022

    Passed: Building - Framing

    Inspected by Troy Crews

  9. Mar 18, 2022

    Cancelled: Electrical - 1st Underground Rough–In

    Inspected by Troy Crews

  10. Mar 18, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  11. Mar 18, 2022

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  12. Apr 1, 2022

    Passed: Building - Insulation

    Inspected by Troy Crews

  13. May 3, 2022

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  14. May 3, 2022

    Release to power company

    Inspected by Troy Crews

  15. May 31, 2022

    Cancelled: Building - Final

    Inspected by Troy Crews

  16. Jun 1, 2022

    Passed: Building - Final

    Inspected by Troy Crews