Permit Details

Permit Search

Permit

New Residential Construction

449 SW ROLLING MEADOWS GLN
FORT WHITE, FL 32038

Permit #
000043061
Application #
52017
Status Completed
  1. Submitted Oct 6, 2021
  2. Issued Oct 28, 2021
  3. Expires Dec 4, 2022
  4. Completed Jun 7, 2022

Property

Parcel #
03767-403
Owner
Kutner David Warren & Deirdre
Acres
5.00
Subdivision
Sedgefield Phase 4
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
89'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0390C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2552
Total Area (Sqft)
4060
Building Height
26
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0864
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Plan Review - Building Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Plumbing Approved
  8. Plan Review - Reviewed
  9. Plan Review - Reviewed
  10. Zoning Review - Reviewed
  11. Final Review - Documents Required
  12. Final Review - Payment Needed
  13. Permit Issued
  14. Final Review - Payment Needed

Contractors

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Tabitha M Sibel

    Rjh Construction

    License
    CCC1331967
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License Expired.

  • Lyndon J Rainbolt

    Rainbolt Tech Services,air Stream

    License
    EC13001835
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Workers Comp Expired.

  • Tabitha M Sibel

    Rjh Construction

    License
    CGC1515388
    Title
    General Contractor
    Role
    Contractor

    County License & State License Expired.

  • Lyndon Rainbolt

    (dba) Rainbolt Tech Services Inc

    License
    CAC1821024
    Title
    Cert. A/c Class “a”
    Role
    Subcontractor

    County License & State License & Workers Comp Expired.

Inspections

  1. Nov 19, 2021

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  2. Nov 19, 2021

    Release to power company

    Inspected by Troy Crews

  3. Dec 6, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Compaction Test Needed

    Inspected by Matt Forsyth

  4. Dec 10, 2021

    Passed: Building - Monolithic Slab

    Fiber-mesh Concrete

    Inspected by Matt Forsyth

  5. Dec 10, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  6. Dec 13, 2021

    Release to power company

    Inspected by Melissa Garber

  7. Feb 2, 2022

    Failed: Building - Masonry Wall Reinforcing

    Need Finished Floor Confirmation From Surveyor Prior To Next Inspection

    Inspected by Troy Crews

  8. Mar 1, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  9. Mar 1, 2022

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  10. Mar 1, 2022

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  11. Mar 1, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  12. Mar 1, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  13. Mar 1, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  14. Mar 1, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  15. Mar 18, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  16. Mar 18, 2022

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  17. Mar 22, 2022

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  18. May 6, 2022

    Passed: Electrical - Permanent Power

    Need Drive And Septic Release

    Inspected by Matt Forsyth

  19. May 13, 2022

    Septic Release Inspection

    Need Drive Release rec'd 5.16.22

    Inspected by Health Dept

  20. May 16, 2022

    Release to power company

    Rec'd Driveway Final 5.16.22

    Inspected by Matt Forsyth

  21. May 27, 2022

    Cancelled: Electrical - Permanent Power

    Inspected by Matt Forsyth

  22. May 27, 2022

    Failed: Building - Final

    Need Power To Island

    Inspected by Matt Forsyth

  23. Jun 6, 2022

    Rescheduled 6/7/2022:Building - Final

    Inspected by Matt Forsyth

  24. Jun 7, 2022

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents