Permit Details

Permit Search

Permit

New Residential Construction

382 SW DUSK GLN
LAKE CITY, FL 32024

Permit #
000043053
Application #
46224
Status Completed
  1. Submitted Sep 22, 2021
  2. Issued Oct 27, 2021
  3. Expires May 15, 2023
  4. Completed Nov 16, 2022

Property

Parcel #
03235-004
Owner
Hannah Joshua Steven & Kendall
Acres
11.54
Subdivision
Division Of Land - Genience Acres
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0380C
This is the construction of a
Single Family Dwelling
Stories
1
Heated Area (Sqft)
2530
Total Area (Sqft)
4047
Building Height
27
Septic# (00-0000) or (X00-000)
21-0789
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Plan Review - Plumbing Approved
  5. Plan Review - Mechanical Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Building Approved
  8. Plan Review - Reviewed
  9. Zoning Review - Reviewed
  10. Final Review - Payment Needed
  11. Permit Issued
  12. Final Review - Payment Needed

Contractors

  • Matthew Hentzelman

    Trademark Construction Group Inc.

    License
    CGC1514780
    Title
    General Contractor
    Role
    Contractor

    County License & State License Expired.

  • Roger Whiddon

    Lake City Plumbing Inc

    License
    CFC1428686
    Title
    Cert Plumbing
    Role
    Subcontractor
  • David P Wood

    Wood's Electrical Services Inc

    License
    EC13002213
    Title
    Electrical Contractor
    Role
    Subcontractor
  • David E Hall

    David Hall's Air Cond & Heating Svc,inc.

    License
    CAC057424
    Title
    Class B A/c Contractor
    Role
    Subcontractor

    Workers Comp Expired.

  • Michael Towne

    Towne Construction Group

    License
    CCC1330125
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. Jan 19, 2022

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. Jan 19, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Jan 21, 2022

    Failed: Electrical - Temporary Service

    Need Ground Fault On Receptacles Our Protection At Breaker

    Inspected by Matt Forsyth

  4. Jan 26, 2022

    Passed: Electrical - Temporary Service

    Item Addressed

    Inspected by Matt Forsyth

  5. Jan 26, 2022

    Release to power company

    Inspected by Matt Forsyth

  6. Feb 14, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Under Slab Water Supply Also Inspected

    Inspected by Matt Forsyth

  7. Feb 28, 2022

    Passed: Building - Slab

    Fibermesh Concrete Being Used

    Inspected by Matt Forsyth

  8. May 20, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  9. May 20, 2022

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  10. Jun 22, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  11. Jul 8, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  12. Jul 8, 2022

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  13. Jul 8, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  14. Jul 27, 2022

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  15. Sep 28, 2022

    Passed: Electrical - Permanent Power

    Need Septic Release

    Inspected by Matt Forsyth

  16. Sep 28, 2022

    Septic Release Inspection

    Inspected by Health Dept

  17. Nov 16, 2022

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents