Permit Details

Permit Search

Permit

Roof Replacement or Repair

226 SW PINE FOREST CT
LAKE CITY, FL 32024

Permit #
000043024
Application #
52204
Status Completed
  1. Submitted Oct 20, 2021
  2. Issued Oct 25, 2021
  3. Expires May 3, 2022
  4. Completed Nov 4, 2021

Property

Parcel #
02829-055
Owner
Kathryn Adams
Acres
1.01
Subdivision
Pine Forest
Zoning
RR
Flood zone
X
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0289D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
REMOVE EXISTING ROOF AND INSTALL ASPHALT SHINGLES
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
3600
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL5444-R16
Product Manufacturer
CERTAINTEED
Product Description
3-tab, 4-tab, strip (no-cut-outs), laminated and architectural asphalt roof shingles
Building Code Edition
2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Repair Existing
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Final Review - Documents Required
  3. Final Review - Payment Needed
  4. Permit Issued

Contractors

  • Daniel Dufresne

    Covenant Roofing & Construction Inc

    License
    CCC1332763
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Oct 29, 2021

    Passed: Re-Roof - In Progress

    Double Underlayment Installed

    Inspected by Matt Forsyth

  2. Nov 4, 2021

    Passed: Re-Roof - Final

    Inspected by Matt Forsyth