Permit Details

Permit Search

Permit

New Residential Construction

372 SW SUNDAY GLN
LAKE CITY, FL 32024

Permit #
000042956
Application #
51560
Status Completed
  1. Submitted Oct 13, 2021
  2. Issued Oct 13, 2021
  3. Expires Sep 26, 2022
  4. Completed Mar 30, 2022

Property

Parcel #
03271-003
Owner
Haddox Mark E & Bobbie E
Acres
10.38
Subdivision
—
Zoning
ESA-2
Flood zone
A
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
67'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0380C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30
Setback Side 1
25
Setback Side 2
25
Setbacks Rear
25
Stories
1
Heated Area (Sqft)
800
Total Area (Sqft)
1711
Building Height
19
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
in-law suite
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0814
If Other, explain the use of the structure.
in-law suite
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Zoning Review - Reviewed
  3. Plan Review - Plumbing Approved
  4. Plan Review - Mechanical Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Building Approved
  7. Plan Review - Reviewed
  8. Zoning Review - Reviewed
  9. Final Review - Documents Required
  10. Final Review - Documents Required
  11. Permit Issued

Contractors

  • Mark Haddox

    Woodman Park Builders Inc

    License
    CRC1329442
    Title
    Residential Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Marcus Matthews

    Matthews Electric Llc

    License
    EC13005459
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Daniel Mossburg

    Live Oak Plumbing, Inc.

    License
    CFC1427438
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Anthony R Franks

    Franks & Lane Heating And Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Oct 14, 2021

    Septic Release Inspection

    Inspected by Health Dept

  2. Oct 19, 2021

    Cancelled: Building - Footer

    Inspected by Melissa Garber

  3. Oct 19, 2021

    Cancelled: Engineering - Setbacks

    Inspected by Melissa Garber

  4. Oct 19, 2021

    Passed: Building - Footer

    Inspected by Matt Forsyth

  5. Oct 19, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  6. Nov 17, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  7. Nov 23, 2021

    Passed: Building - Slab

    Inspected by Troy Crews

  8. Dec 10, 2021

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  9. Dec 10, 2021

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  10. Dec 17, 2021

    Passed: Electrical - 2nd Rough-In

    14-2 Romex Inside Vaulted Ceiling

    Inspected by Matt Forsyth

  11. Dec 17, 2021

    Failed: Plumbing/Gas - 2nd Rough-In

    Water Lines Not Under Pressure

    Inspected by Matt Forsyth

  12. Dec 17, 2021

    Failed: Building - Strapping

    Need Gable Strapping

    Inspected by Matt Forsyth

  13. Dec 17, 2021

    Passed: Building - Framing

    Inspected by Matt Forsyth

  14. Dec 30, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  15. Dec 30, 2021

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Water Test Completed On Tub

    Inspected by Matt Forsyth

  16. Jan 11, 2022

    Passed: Mechanical - Rough In

    Bath Exhaust Fan No Strap And Needs Ul181 Tape On Connections

    Inspected by Anthony Aslan

  17. Jan 18, 2022

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  18. Feb 23, 2022

    Passed: Electrical - Permanent Power

    Inspected by Anthony Aslan

  19. Feb 23, 2022

    Release to power company

    Inspected by Anthony Aslan

  20. Mar 30, 2022

    Passed: Building - Final

    Inspected by Anthony Aslan

Documents