| Finished floor requirement |
|
| Fema map number |
12023C0490C |
| Type Roofing Job |
Overlay with Metal |
| Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
Install 26 gauge metal panels over 1x4 pine purlins attached to trusses with two 3" all weather deck screws over existing shingles. Repairs to decking to be made at two locations and cricket to be constructed at chimney. |
| Type of structure |
House |
| Commercial or Residential |
Residential |
| Roof Area (for this job) Sq Ft |
3200 |
| No. of Stories |
1 |
| Roof Pitch |
2:12 to 4:12 |
| Is the existing roof being removed? |
No |
| Explain if not removing the existing roofing material? |
As stated above install 1x4 syp purlins over shingles fastened to trusses with two 3" decking screws repairs to be made to decking. |
| Type of New Roofing Product |
Metal |
| Florida Product Approval Number |
12725.3 R3 |
| Product Manufacturer |
Reeds Metal |
| Product Description |
26 gauge ribbed residential Galvalume |
| Building Code Edition |
2020 Florida Building Code 7th Edition and Florida Statute 553.844 |
| Sealed roof decking options: (Must select an option.) |
Other (explain) |
| Sealed roof decking explanation for other option. |
No tear off being done. Installing 1x4 purlins over existing shingles. |
| Ventilation: |
Ridge Vent |
| Flashing: |
Replace All |
| Drip Edge: |
Replace All |
| Valley Treatment: |
New Metal |
| Any cable and/or race-way wiring located on or within the roof assembly? |
No |