Permit Details

Permit Search

Permit

Roof Replacement or Repair

146 SE GREG PL
LAKE CITY, FL 32025

Permit #
000042626
Application #
50364
Status Completed
  1. Submitted Aug 26, 2021
  2. Issued Aug 26, 2021
  3. Expires Mar 13, 2022
  4. Completed Sep 14, 2021

Property

Parcel #
06990-000
Owner
Baker Betty Jo
Acres
0.24
Subdivision
Bellaire
Zoning
RSF-2
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0311D
Type Roofing Job
Overlay with Metal
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
2071
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
No
Type of New Roofing Product
Metal
Florida Product Approval Number
FL17992_R2_II_29 GA
Product Manufacturer
Capital Metal Product Approval
Product Description
29 Gauge Metal
Building Code Edition
2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Final Review - Corrections Needed
  3. Final Review - Payment Needed
  4. Permit Issued

Contractors

  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Contractor

Inspections

  1. Sep 10, 2021

    Passed: Re-Roof - In Progress

    Inspected by Troy Crews

  2. Sep 14, 2021

    Passed: Re-Roof - Final

    Inspected by Troy Crews