Permit Details

Permit Search

Permit

New Residential Construction

300 SW LEGREE TER
FORT WHITE, FL 32038

Permit #
000042482
Application #
49546
Status Completed
  1. Submitted Dec 2, 2021
  2. Issued Sep 23, 2021
  3. Expires Mar 9, 2027
  4. Completed Sep 11, 2026

Property

Parcel #
04076-144
Owner
Prior Rebecca A Trustee Of The Rebecca A Prior Living Trust
Acres
5.00
Subdivision
Parker Woods
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
Culvert Waiver: 000042483

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
103.39'
Requirement needed
By Nailing Inspection
Document needed is
NA
Document receieved
Yes
Fema map number
12023C0495C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
792
Total Area (Sqft)
1680
Building Height
15
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
SINGLE FAMILY DWELLING
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0381
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
Other (explain)
Sealed roof decking explanation for other option.
PER ENGINEERING CALLS FOR 3" CLOSED CELL FOAM INSULATION (PG 4 OF DRAWINGS) - NO UNDERLAYMENT REQUIRED

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Zoning Review - Reviewed
  3. Plan Review - Documents Required
  4. Final Review - Documents Required
  5. Plan Review - Plumbing Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Electrical Approved
  8. Plan Review - Building Approved
  9. Plan Review - Reviewed
  10. Final Review - Processing
  11. Permit Issued
  12. Permit reissued to reflect updated information.
  13. Permit reissued to reflect updated information.
  14. Permit reissued to reflect updated information.
  15. Final Review - Payment Needed
  16. Permit Status Update Notification

Contractors

This is an owner-builder project.

  • Aaron Hokanson

    Aaron's Plumbing Corporation

    License
    CFC1426264
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Dioslay Hondares

    A-1 Florida Electric Contractor Corp

    License
    EC13006229
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Sep 8, 2021

    Passed: Electrical - Temporary Service

    Inspected by Anthony Aslan

  2. Sep 8, 2021

    Release to power company

    Inspected by Anthony Aslan

  3. Nov 24, 2021

    Rescheduled 11/30/2021:Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  4. Nov 29, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  5. Nov 30, 2021

    Cancelled: Building - Slab

    Inspected by Anthony Aslan

  6. Mar 4, 2022

    Passed: Building - Slab

    Inspected by Anthony Aslan

  7. May 10, 2022

    Septic Release Inspection

    Inspected by Health Dept

  8. Aug 2, 2022

    Passed: Building - Framing

    Inspected by Anthony Aslan

  9. Aug 22, 2022

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  10. Nov 16, 2022

    Cancelled: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  11. Nov 16, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  12. May 4, 2023

    Passed: Engineering - Spot Check

    Spot Check Electrical

    Inspected by Anthony Aslan

  13. Jul 11, 2023

    Cancelled: Electrical - 1st Underground Rough–In

    Inspected by Anthony Aslan

  14. Sep 27, 2023

    Passed: Mechanical - Rough In

    Gasket Boots Supply & Return

    Inspected by Anthony Aslan

  15. Sep 27, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  16. Oct 23, 2023

    Passed: Building - Insulation

    Inspected by Anthony Aslan

  17. Apr 18, 2024

    Passed: Engineering - Spot Check

    Owner Needs Time To Complete

    Inspected by Troy Crews

  18. Oct 15, 2024

    Passed: Building - Insulation

    Customer Needs More Time

    Inspected by Anthony Aslan

  19. Oct 16, 2024

    Passed: Building - Spot Check

    Customer Needs More Time

    Inspected by Anthony Aslan

  20. Apr 4, 2025

    Passed: Building - Spot Check

    Need More Time Kitchen & Bath

    Inspected by Anthony Aslan

  21. Feb 26, 2026

    Passed: Building - Spot Check

    Inspected by Christian Allen

  22. Sep 8, 2026

    Passed: Building - Spot Check

    Inspected by Troy Crews

  23. Sep 10, 2026

    Passed: Building - Final

    Pending Blower Door And Termite Final

    Inspected by Christian Allen

Documents