Permit Details

Permit Search

Permit

New Residential Construction

132 SW SILVER PALM DR
LAKE CITY, FL 32024

Permit #
000042409
Application #
49700
Status Completed
  1. Submitted Nov 12, 2021
  2. Issued Nov 12, 2021
  3. Expires Jan 13, 2024
  4. Completed Jul 17, 2023

Property

Parcel #
02731-057
Owner
The Preserve At Laurel Lake Inc
Acres
0.25
Subdivision
Preserve At Laurel Lake Unit 1
Zoning
PRD
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
116.6'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0290D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2281
Total Area (Sqft)
3188.4
Building Height
20
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
x-city
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Zoning Review - Reviewed
  4. Plan Review - Corrections Needed
  5. Plan Review - Plumbing Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Electrical Approved
  8. Plan Review - Documents Required
  9. Zoning Review - Reviewed
  10. Final Review - Documents Required
  11. Final Review - Payment Needed
  12. Permit Issued
  13. Permit reissued to reflect updated information.
  14. Final Review - Payment Needed
  15. Final Review - Payment Needed

Contractors

  • Stephen M Brisbois

    Epic Ac Service (dba) Central Home Heating & Air Llc

    License
    CAC1819412
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor
  • Ralph W Laverdure

    Rwl Roofing,llc.

    License
    CCC1328590
    Title
    Roofing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Billy B Rathel Jr

    Five Star Plumbing Big Bend, Inc.

    License
    CFC1427547
    Title
    Cert. Plumbing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Aaron Simque

    Aaron Simque Homes Inc

    License
    RR282811879
    Title
    Residential Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor

Inspections

  1. Aug 18, 2021

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Aug 18, 2021

    Passed: Engineering - Setbacks

    Surveyor Must Confirm Setbacks

    Inspected by Troy Crews

  3. Aug 18, 2021

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  4. Aug 18, 2021

    Release to power company

    Inspected by Troy Crews

  5. Sep 24, 2021

    Rescheduled 9/27/2021:Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  6. Sep 27, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  7. Sep 30, 2021

    Passed: Building - Slab

    Inspected by Troy Crews

  8. Nov 2, 2021

    Failed: Building - Footer

    Must Have Engineer Letter Surveyor Letter Came In Below Plat Requirement.

    Inspected by Troy Crews

  9. Nov 2, 2021

    Cancelled: Engineering - Setbacks

    Inspected by Troy Crews

  10. Nov 15, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  11. Nov 15, 2021

    Passed: Building - Framing

    Inspected by Troy Crews

  12. Nov 15, 2021

    Passed: Building - Strapping

    Inspected by Troy Crews

  13. Nov 15, 2021

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  14. Nov 15, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  15. Nov 15, 2021

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  16. Nov 15, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  17. Nov 29, 2021

    Passed: Building - Insulation

    Inspected by Troy Crews

  18. Apr 27, 2022

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  19. Apr 27, 2022

    Release to power company

    Inspected by Troy Crews

  20. Jul 17, 2023

    Passed: Building - Final

    Inspected by Anthony Aslan

Documents