Permit Details

Permit Search

Permit

New Residential Construction

372 SW BLACKPINE TERR
LAKE CITY, FL 32024

Permit #
000042282
Application #
49579
Status Completed
  1. Submitted Jun 9, 2021
  2. Issued Oct 1, 2021
  3. Expires Nov 27, 2022
  4. Completed May 31, 2022

Property

Parcel #
03087-117
Owner
Terry Jones And Denna Freeman
Acres
0.70
Subdivision
Forest Country Sixth Addition
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
106'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0289D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2907
Total Area (Sqft)
4138
Building Height
25
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0474
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Application pending.
  2. Point Review - On Hold-Incomplete
  3. Point Review - Printed-Online Application
  4. Point Review - Reviewed
  5. Zoning Review - Reviewed
  6. Plan Review - Documents Required
  7. Plan Review - Documents Required
  8. Plan Review - Documents Required
  9. Plan Review - Documents Required
  10. Plan Review - Plumbing Approved
  11. Plan Review - Mechanical Approved
  12. Plan Review - Electrical Approved
  13. Plan Review - Building Approved
  14. Plan Review - Reviewed
  15. Zoning Review - Reviewed
  16. Final Review - Reviewed
  17. Final Review - Payment Needed
  18. Permit Issued
  19. Permit reissued to reflect updated information.
  20. Final Review - Payment Needed

Contractors

  • Josh Sparks

    Sparks Construction

    License
    CBC1252260
    Title
    Building Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Ralph W Laverdure

    Rwl Roofing,llc.

    License
    CCC1328590
    Title
    Roofing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Benjamin L Sparks

    Line Electric Company Llc

    License
    EC13009101
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License Expired.

  • Stephen M Brisbois

    Epic Ac Service (dba) Central Home Heating & Air Llc

    License
    CAC1819412
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

Inspections

  1. Sep 21, 2021

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. Sep 21, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Oct 14, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  4. Nov 17, 2021

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Jan 3, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  6. Jan 3, 2022

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  7. Jan 3, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  8. Jan 14, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  9. Jan 14, 2022

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  10. Jan 14, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Tub Was Water Tested

    Inspected by Matt Forsyth

  11. Feb 15, 2022

    Passed: Building - Insulation

    Spray Foam Walls And Ceiling

    Inspected by Matt Forsyth

  12. Apr 13, 2022

    Septic Release Inspection

    Inspected by Health Dept

  13. Apr 14, 2022

    Passed: Electrical - Permanent Power

    Need Driveway Release

    Inspected by Matt Forsyth

  14. Apr 21, 2022

    Release to power company

    Inspected by Melissa Garber

  15. May 17, 2022

    Failed: Building - Final

    Ele Panel Not Labeled , Recpt. In Garage Showing Open Ground, Back Porch Gfci Not Working Also Need Bdt Test

    Inspected by Matt Forsyth

  16. May 20, 2022

    Failed: Building - Final

    Stove Venting Document

    Inspected by Matt Forsyth

  17. May 31, 2022

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents