Permit Details

Permit Search

Permit

New Residential Construction

140 SW SQUIRREL CT
FORT WHITE, FL 32038

Permit #
000041919
Application #
48906
Status Completed
  1. Submitted Jan 21, 2022
  2. Issued May 14, 2021
  3. Expires Sep 27, 2022
  4. Completed Mar 31, 2022

Property

Parcel #
03816-321
Owner
Dawes Heidi Jean & Dawes Steven William
Acres
10.02
Subdivision
Tustenuggee Trails Unr
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0485C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1358
Total Area (Sqft)
2331
Building Height
19
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0332
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Zoning Review - Reviewed
  2. Point Review - Received-Hard Copy Application
  3. Plan Review - Reviewed
  4. Zoning Review - Reviewed
  5. Final Review - Documents Required
  6. Final Review - Payment Needed
  7. Permit Issued
  8. Final Review - Payment Needed

Contractors

  • Mark Haddox

    Woodman Park Builders Inc

    License
    CRC1329442
    Title
    Residential Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Anthony R Franks

    Franks & Lane Heating And Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

  • Marcus Matthews

    Matthews Electric Llc

    License
    EC13005459
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Daniel Mossburg

    Live Oak Plumbing, Inc.

    License
    CFC1427438
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. May 24, 2021

    Passed: Building - Footer

    Inspected by Troy Crews

  2. May 24, 2021

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Jun 14, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  4. Jun 22, 2021

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Jul 27, 2021

    Failed: Building - Wall Sheathing

    Could Not Open Lock

    Inspected by Troy Crews

  6. Jul 29, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  7. Sep 9, 2021

    Failed: Building - Ext Strapping/Wall Sheathing

    Front Porch Post Not Strapped

    Inspected by Troy Crews

  8. Sep 9, 2021

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Troy Crews

  9. Sep 9, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  10. Sep 9, 2021

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  11. Sep 9, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  12. Sep 9, 2021

    Cancelled: Building - Strapping

    Inspected by Troy Crews

  13. Sep 9, 2021

    Failed: Building - Framing

    Front Porch Post Not Strapped Call Back In With Insulation

    Inspected by Troy Crews

  14. Oct 13, 2021

    Passed: Building - Insulation

    Inspected by Troy Crews

  15. Oct 13, 2021

    Passed: Building - Framing

    Front Post Strapped

    Inspected by Troy Crews

  16. Jan 20, 2022

    Passed: Electrical - Permanent Power

    Need Septic Fonal

    Inspected by Troy Crews

  17. Jan 21, 2022

    Release to power company

    Inspected by Melissa Garber

  18. Jan 21, 2022

    Septic Release Inspection

    Inspected by Health Dept

  19. Jan 25, 2022

    Release to power company

    Inspected by Melissa Garber

  20. Mar 31, 2022

    Passed: Building - Final

    Inspected by Troy Crews