Permit Details

Permit Search

Permit

New Residential Construction

719 SW HAPPY JACK DR
LAKE CITY, FL 32024

Permit #
000041637
Application #
48776
Status Completed
  1. Submitted Oct 13, 2021
  2. Issued Oct 13, 2021
  3. Expires Apr 12, 2022
  4. Completed Oct 14, 2021

Property

Parcel #
00415-108
Owner
Alex & Tammy Winnett
Acres
10.05
Subdivision
Southwest Estates Unr
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0360C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2307
Total Area (Sqft)
2819
Building Height
19
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0247
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
Other (explain)

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Zoning Review - Reviewed
  4. Plan Review - Reviewed
  5. Zoning Review - Reviewed
  6. Final Review - Documents Required
  7. Final Review - Payment Needed
  8. Permit Issued
  9. Final Review - Payment Needed
  10. Final Review - Payment Needed
  11. Permit Renewed

Contractors

  • Mark Haddox

    Woodman Park Builders Inc

    License
    CRC1329442
    Title
    Residential Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Anthony R Franks

    Franks & Lane Heating And Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

  • Daniel Mossburg

    Live Oak Plumbing, Inc.

    License
    CFC1427438
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Marcus Matthews

    Matthews Electric Llc

    License
    EC13005459
    Title
    Electrical Contractor
    Role
    Subcontractor

Inspections

  1. Apr 14, 2021

    Failed: Building - Footer

    Need More Rebar Chairs To Prevent Sagging Of Rebar It Is To Close To Bottom Of Footing.rebar Not Clearing Side Of Footing Needs To Be Cut Off

    Inspected by Matt Forsyth

  2. Apr 14, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Apr 15, 2021

    Passed: Building - Footer

    Inspected by Matt Forsyth

  4. Apr 15, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  5. May 5, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  6. May 12, 2021

    Passed: Building - Slab

    Inspected by Matt Forsyth

  7. Jun 22, 2021

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  8. Jun 22, 2021

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  9. Jul 20, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  10. Jul 20, 2021

    Passed: Building - Framing

    Inspected by Matt Forsyth

  11. Jul 20, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  12. Jul 20, 2021

    Failed: Mechanical - Rough In

    Dryer Vent Stack Needs Furred Out

    Inspected by Matt Forsyth

  13. Jul 30, 2021

    Passed: Building - Insulation

    Walls And Vaulted Ceiling Only

    Inspected by Matt Forsyth

  14. Jul 30, 2021

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  15. Jul 30, 2021

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Matt Forsyth

  16. Aug 12, 2021

    Failed: Mechanical - Rough In

    Hearth Needs To Be Built Deeper 16 Inches

    Inspected by Matt Forsyth

  17. Aug 18, 2021

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  18. Sep 2, 2021

    Passed: Electrical - Permanent Power

    Need Septic Final

    Inspected by Matt Forsyth

  19. Sep 8, 2021

    Release to power company

    Inspected by Melissa Garber

  20. Sep 8, 2021

    Septic Release Inspection

    Inspected by Health Dept

  21. Oct 14, 2021

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents