Permit Details

Permit Search

Permit

New Residential Construction

395 SW MARYNIK DR
HIGH SPRINGS, FL 32643

Permit #
000041609
Application #
48706
Status Completed
  1. Submitted Mar 12, 2021
  2. Issued Mar 26, 2021
  3. Expires May 17, 2022
  4. Completed Nov 18, 2021

Property

Parcel #
10006-205
Owner
Floyd, Albert
Acres
5.10
Subdivision
River Rise Residential Unit 1
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0513C
This is the construction of a
Single Family Dwelling
Setbacks Front
30
Setback Side 1
25
Setback Side 2
25
Setbacks Rear
25
Stories
1
Heated Area (Sqft)
2285
Total Area (Sqft)
3521
Building Height
25.5
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0249

Status & Review History

  1. Application pending.
  2. Point Review - On Hold-Incomplete
  3. Point Review - Printed-Online Application
  4. Plan Review - Reviewed
  5. Zoning Review - Reviewed
  6. Final Review - Documents Required
  7. Final Review - Payment Needed
  8. Permit Issued
  9. Final Review - Payment Needed

Contractors

  • Stuart L Amira

    Amira Builders, Inc.

    License
    CRC1327171
    Title
    Cert. Residential
    Role
    Subcontractor

    County License & State License Expired.

  • James Butler Jr

    Butler Plumbing Of Gainesville Inc

    License
    CFC057960
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • David J Pabst

    Whittle Roofing Company, Inc.

    License
    CCC1326372
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License Expired.

  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Robert M Bounds

    Bounds Heating & Air Inc

    License
    CAC057642
    Title
    Class A A/c
    Role
    Subcontractor

Inspections

  1. Apr 27, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    90psi @ Inspection

    Inspected by Anthony Aslan

  2. Apr 30, 2021

    Passed: Electrical - Temporary Service

    Take Pictures Of Grounding Lug On Rod.

    Inspected by Anthony Aslan

  3. Apr 30, 2021

    Release to power company

    Inspected by Anthony Aslan

  4. May 10, 2021

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Anthony Aslan

  5. May 10, 2021

    Passed: Building - Slab

    Inspected by Anthony Aslan

  6. Jun 15, 2021

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  7. Jun 15, 2021

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  8. Jun 23, 2021

    Passed: Building - Framing

    Headers In Left Side Of House

    Inspected by Anthony Aslan

  9. Jun 23, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  10. Jul 6, 2021

    Rescheduled 7/8/2021:Electrical - 2nd Rough-In

    Inspected by Troy Crews

  11. Jul 6, 2021

    Rescheduled 7/8/2021:Mechanical - Rough In

    Inspected by Troy Crews

  12. Jul 7, 2021

    Cancelled: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  13. Jul 7, 2021

    Cancelled: Mechanical - Rough In

    Inspected by Anthony Aslan

  14. Jul 8, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  15. Jul 8, 2021

    Failed: Mechanical - Rough In

    Missing Screws In Kitchen Exhaust Piping

    Inspected by Anthony Aslan

  16. Jul 12, 2021

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  17. Jul 22, 2021

    Passed: Building - Insulation

    Inspected by Anthony Aslan

  18. Aug 23, 2021

    Cancelled: Building - Insulation

    Inspected by Anthony Aslan

  19. Aug 27, 2021

    Septic Release Inspection

    Inspected by Health Dept

  20. Aug 30, 2021

    Passed: Electrical - Permanent Power

    Need Pictures Of Lock On Panel

    Inspected by Anthony Aslan

  21. Aug 30, 2021

    Release to power company

    Inspected by Anthony Aslan

  22. Nov 18, 2021

    Cancelled: Building - Final

    Inspected by Anthony Aslan

  23. Nov 18, 2021

    Passed: Building - Final

    Inspected by Troy Crews

Documents