Permit Details

Permit Search

Permit

New Residential Construction

715 SW RUM ISLAND TER
FT. WHITE, FL 32038

Permit #
000041361
Application #
48233
Status Completed
  1. Submitted Jan 21, 2021
  2. Issued Feb 19, 2021
  3. Expires Feb 14, 2022
  4. Completed Aug 18, 2021

Property

Parcel #
04321-074
Owner
Newton Roger Wayne
Acres
9.83
Subdivision
Rum Island Ranches Unr
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0531C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1664
Total Area (Sqft)
2233
Building Height
16
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0007

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Zoning Review - Reviewed
  5. Plan Review - Documents Required
  6. Plan Review - Documents Required
  7. Zoning Review - Reviewed
  8. Plan Review - Reviewed
  9. Final Review - Reviewed
  10. Final Review - Payment Needed
  11. Permit Issued
  12. Final Review - Payment Needed

Contractors

  • Patricia S Dees

    Steve Smith Construction, Inc.

    License
    CBC1256817
    Title
    Cert. Building
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Mario M Spadavecchia

    A & M Plumbing Enterprises Inc

    License
    CFC1426551
    Title
    Cert. Plumbing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  • George W Grimm

    George Grimm Electric, Inc.

    License
    EC13007091
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Richard A Hunt

    Todays Heating & Air Inc

    License
    CAC012076
    Title
    Cert. A/c Class “a”
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Feb 26, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  2. Mar 4, 2021

    Passed: Building - Monolithic Slab

    Inspected by Anthony Aslan

  3. Mar 4, 2021

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  4. Mar 26, 2021

    Passed: Building - Lintel/Tie Beam

    Inspected by Anthony Aslan

  5. Mar 26, 2021

    Passed: Building - Masonry Wall Reinforcing

    Inspected by Anthony Aslan

  6. Mar 26, 2021

    Failed: Electrical - Temporary Service

    No Temp Pole

    Inspected by Anthony Aslan

  7. Mar 31, 2021

    Passed: Electrical - Temporary Service

    Inspected by Anthony Aslan

  8. Mar 31, 2021

    Release to power company

    Inspected by Anthony Aslan

  9. Apr 6, 2021

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  10. Apr 6, 2021

    Passed: Building - Strapping

    Inspected by Anthony Aslan

  11. Apr 6, 2021

    Passed: Building - Framing

    Inspected by Anthony Aslan

  12. Apr 15, 2021

    Cancelled: Electrical - 2nd Rough-In

    No Ready

    Inspected by Anthony Aslan

  13. Apr 15, 2021

    Cancelled: Mechanical - Rough In

    No Ready

    Inspected by Anthony Aslan

  14. Apr 15, 2021

    Cancelled: Plumbing/Gas - 2nd Rough-In

    No Ready

    Inspected by Anthony Aslan

  15. Apr 20, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  16. Apr 20, 2021

    Passed: Building - Insulation

    Partial Inspection, Check At Final

    Inspected by Anthony Aslan

  17. Apr 20, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  18. Apr 20, 2021

    Failed: Mechanical - Rough In

    Dryer Box Pipe Not Through Box

    Inspected by Anthony Aslan

  19. May 7, 2021

    Cancelled: Building - Insulation

    Inspected by Anthony Aslan

  20. May 7, 2021

    Passed: Building - Framing

    Windows Installed

    Inspected by Anthony Aslan

  21. May 7, 2021

    Passed: Mechanical - Rough In

    Dryer Box Lifted

    Inspected by Anthony Aslan

  22. Jul 22, 2021

    Passed: Electrical - Permanent Power

    Need Septic Releasr

    Inspected by Anthony Aslan

  23. Jul 26, 2021

    Release to power company

    Inspected by Laurie Hodson

  24. Jul 26, 2021

    Septic Release Inspection

    Inspected by Health Dept

  25. Aug 18, 2021

    Passed: Building - Final

    Insulation Checked Good

    Inspected by Anthony Aslan

  26. Requested

    Building - Fire Rated Wall

    Awaiting inspection

  27. Requested

    Electrical - 2nd Rough-In

    Awaiting inspection

  28. Requested

    Plumbing/Gas - 2nd Rough-In

    Awaiting inspection

  29. Requested

    Electrical - 2nd Rough-In

    Awaiting inspection

  30. Requested

    Plumbing/Gas - 2nd Rough-In

    Awaiting inspection

  31. Requested

    Electrical - Permanent Power

    Awaiting inspection

  32. Requested

    Electrical - 2nd Rough-In

    Awaiting inspection

  33. Requested

    Plumbing/Gas - 2nd Rough-In

    Awaiting inspection

  34. Requested

    Electrical - Permanent Power

    Awaiting inspection

  35. Requested

    Electrical - 2nd Rough-In

    Awaiting inspection

  36. Requested

    Plumbing/Gas - 2nd Rough-In

    Awaiting inspection

Documents