Permit Details

Permit Search

Permit

New Residential Construction

180 NW GOBBLER DR
LAKE CITY, FL 32055

Permit #
000041043
Application #
47599
Status Completed
  1. Submitted Dec 20, 2021
  2. Issued Jun 8, 2021
  3. Expires Jul 6, 2022
  4. Completed Jan 7, 2022

Property

Parcel #
02279-129
Owner
Woodborough North Llc
Acres
0.28
Subdivision
Turkey Creek Unit 1
Zoning
PRD
Flood zone
X
District
1

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
158.56'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0283D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
20'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
20'
Stories
1
Heated Area (Sqft)
1703
Total Area (Sqft)
2518
Building Height
22
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
20-0891

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Zoning Review - On Hold-Incomplete
  3. Zoning Review - Reviewed
  4. Plan Review - Reviewed
  5. Zoning Review - Reviewed
  6. Final Review - Documents Required
  7. Final Review - Payment Needed
  8. Permit Issued
  9. Plan Review - Reviewed
  10. Permit reissued to reflect updated information.
  11. Permit reissued to reflect updated information.
  12. Final Review - Payment Needed

Contractors

  • James Lipscomb

    Lipscomb & Eagle Development Inc

    License
    CBC1253543
    Title
    Building Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Mervin L Hines

    Hines Electrical & Communication Inc

    License
    EC13003393
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • David E Hall

    David Hall's Air Cond & Heating Svc,inc.

    License
    CAC057424
    Title
    Class B A/c Contractor
    Role
    Subcontractor

    Workers Comp Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Kevin L Bedenbaugh Jr

    Plumb Level Construction Co Llc

    License
    CCC1329482
    Title
    Roofing Contractor
    Role
    Subcontractor

Inspections

  1. Apr 30, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  2. Apr 30, 2021

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Anthony Aslan

  3. May 7, 2021

    Passed: Building - Monolithic Slab

    Inspected by Anthony Aslan

  4. May 7, 2021

    Passed: Engineering - Setbacks

    Tight Lot Lines Need Survey Confirmation.

    Inspected by Anthony Aslan

  5. Jun 9, 2021

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  6. Jun 9, 2021

    Passed: Building - Wall Sheathing

    Picture On Gable Straps

    Inspected by Anthony Aslan

  7. Jun 9, 2021

    Passed: Building - Strapping

    Porch Post

    Inspected by Anthony Aslan

  8. Jun 11, 2021

    Passed: Building - Framing

    Gable Small Truss At Entrance Needs Heavy Strapping. Truss Plan Show 695 & 814 Uplift On Each End.

    Inspected by Anthony Aslan

  9. Jul 9, 2021

    Failed: Electrical - 2nd Rough-In

    Smoke Detector To Close To Main Return In Hallway.

    Inspected by Anthony Aslan

  10. Jul 9, 2021

    Failed: Mechanical - Rough In

    Laundry Wall Needs To Be Furred Out For Dryer Vent, Dryer Box Needs To Be Change Out So That Dryer Pipe Is Not Oval. main Return Flex Needs Strap At Boot, 1 1/2 Times The Diameter From Proper Flow. bath Exhaust Fans Missing Strapping On Venting. plenums Minimum 4" Clearance Around Plenums.

    Inspected by Anthony Aslan

  11. Jul 9, 2021

    Failed: Plumbing/Gas - 2nd Rough-In

    Nail Guards Missing Master Bed, Supply Lines At Water Heater, Hall Bath Vent And Shower Supply Lines.

    Inspected by Anthony Aslan

  12. Jul 20, 2021

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  13. Jul 20, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  14. Jul 20, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  15. Jul 26, 2021

    Passed: Building - Insulation

    Inspected by Anthony Aslan

  16. Dec 14, 2021

    Septic Release Inspection

    Inspected by Health Dept

  17. Dec 16, 2021

    Passed: Electrical - Permanent Power

    Need Driveway Release

    Inspected by Anthony Aslan

  18. Dec 20, 2021

    Release to power company

    Inspected by Anthony Aslan

  19. Dec 20, 2021

    Release to power company

    Inspected by Laurie Hodson

  20. Jan 7, 2022

    Passed: Building - Final

    Inspected by Anthony Aslan