Permit Details

Permit Search

Permit

New Residential Construction

251 SW OLD CYPRESS WAY
LAKE CITY, FL 32024

Permit #
000038057
Application #
40773
Status Completed
  1. Submitted May 1, 2019
  2. Issued May 1, 2019
  3. Expires Mar 23, 2020
  4. Completed Sep 25, 2019

Property

Parcel #
02439-134
Owner
Gary Sorensen
Acres
0.33
Subdivision
The Reserve At Jewel Lake
Zoning
PRD
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0290D
This is the construction of a
SFD/UTILITY
Setbacks Front
25.00
Setback Side 1
10.00
Setback Side 2
10.00
Setbacks Rear
15.00
Stories
1
Heated Area (Sqft)
1636.00
Total Area (Sqft)
2316.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
X-CITY

Status & Review History

No status updates yet.

Contractors

  • Gerald M. Smith, Sr.

    License
    CBC1254161
    Title
    —
    Role
    —

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Jun 6, 2019

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Jun 6, 2019

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Jun 18, 2019

    Passed: Plumbing/Gas - Underground Rough-In

    Inspected by Tommy Matthews

  4. Jun 24, 2019

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Jul 8, 2019

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  6. Jul 8, 2019

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  7. Jul 10, 2019

    Cancelled: Building - Ext Strapping/Wall Sheathing

    Inspected by Laurie Hodson

  8. Jul 10, 2019

    Cancelled: Building - Framing

    Inspected by Troy Crews

  9. Jul 15, 2019

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Troy Crews

  10. Jul 16, 2019

    Passed: Building - Framing

    Inspected by Troy Crews

  11. Jul 25, 2019

    Passed: Electrical - Rough In

    Inspected by Tommy Matthews

  12. Jul 25, 2019

    Passed: Mechanical - Rough In

    Inspected by Tommy Matthews

  13. Jul 29, 2019

    Passed: Building - Insulation

    Inspected by Troy Crews

  14. Aug 22, 2019

    Cancelled: Electrical - Temporary Service

    Inspected by Troy Crews

  15. Aug 22, 2019

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  16. Aug 22, 2019

    Release to power company

    Inspected by Troy Crews

  17. Sep 25, 2019

    Passed: Building - Final

    Inspected by Troy Crews